PerkinElmer

Search Results for 'ICP'

Products & Services (1394)
Filters:

Filters :

Show results for
Product Type
  • Accessories (190)
  • Consumables (1175)
  • Instruments (5)
  • Reagents (1)
  • Service Parts (13)
  • Software and Informatics (10)
Color
  • Black/Black (7)
  • Black/Black/Black (1)
  • Black/White (2)
  • Black/White/Black (1)
  • Blue/Blue (1)
  • Gray/Gray (3)
  • Green/Green (1)
  • Green/Yellow (3)
  • Orange/Black (1)
  • Orange/Blue (4)
  • Orange/Green (6)
  • Orange/Orange (1)
  • Orange/Red (5)
  • Orange/White (4)
  • Orange/Yellow (5)
  • Orange/Yellow/Orange (1)
  • Purple/Purple (1)
  • Purple/Purple/Purple (1)
  • Purple/White/Purple (1)
  • Red/Red (5)
  • Red/Red/Red (2)
  • White/Black (1)
  • White/Red (1)
  • White/White (2)
  • White/White/White (1)
  • White/Yellow (1)
  • Yellow/Blue (2)
  • Yellow/Blue/Yellow (1)
  • Yellow/Yellow (1)
Concentration
  • 0.02 % (1)
  • 1 μg/mL (68)
  • 1 μg/mL μg/mL (1)
  • 10 μg/g (3)
  • 10 μg/L (2)
  • 10 μg/mL (12)
  • 100 μg/g (3)
  • 100 μg/mL (1)
  • 1000 μg/g (30)
  • 1000 μg/g (1)
  • 1000 μg/mL (164)
  • 10000 μg/mL (18)
  • 30 μg/g (3)
  • 300 μg/g (3)
  • 50 μg/g (3)
  • 500 μg/g (3)
  • 5000 μg/g (1)
  • 900 μg/g (2)
  • Ca @ 5000 μg/g; P, Zn @ 1600 μg/g (2)
Depth
  • 34.0 cm (1)
  • 41.0 cm (1)
  • 47.0 cm (1)
  • 54.0 cm (1)
  • 63.5 cm (1)
  • 69.0 cm (2)
  • 84.0 cm (1)
Detection Method
  • Radiometric (1)
Grade
  • Pure (224)
  • Pure Plus (127)
Inner Diameter
  • 0.64 mm (1)
  • 0.76 mm (1)
  • 0.062 in (1)
  • 0.13 mm (1)
  • 0.15 mm (1)
  • 0.19 mm (5)
  • 0.20 mm (1)
  • 0.25 mm (4)
  • 0.27 mm (1)
  • 0.30 mm (1)
  • 0.38 mm (6)
  • 0.44 mm (4)
  • 0.5 mm (2)
  • 0.51 mm (5)
  • 0.57 mm (1)
  • 0.64 mm (3)
  • 0.76 mm (8)
  • 0.8 mm (8)
  • 0.85 mm (2)
  • 0.89 mm (1)
  • 0.95 mm (1)
  • 1 mm (1)
  • 1.0 mm (6)
  • 1.02 mm (4)
  • 1.09 mm (1)
  • 1.14 mm (6)
  • 1.2 mm (10)
  • 1.3 mm (2)
  • 1.30 mm (1)
  • 1.42 mm (1)
  • 1.5 mm (10)
  • 1.52 mm (3)
  • 1.6 mm (6)
  • 1.65 mm (1)
  • 1.8 mm (4)
  • 1.85 mm (1)
  • 2.0 mm (26)
  • 2.06 mm (2)
  • 2.5 mm (7)
  • 2.79 mm (1)
  • 3.0 mm (3)
  • 3.17 mm (1)
  • 3.18 mm (2)
  • 9.5 mm (1)
Length
  • 51-100 (4)
Material
  • Alumina (7)
  • Brass (3)
  • Ceramic (8)
  • CTFE (10)
  • Glass (81)
  • Nickel (7)
  • PEEK (17)
  • PEEK/PTFE (3)
  • PFA (90)
  • Platinum (10)
  • Polypropylene (7)
  • PTFE (28)
  • PVC (8)
  • Quartz (126)
  • Ryton (6)
  • Santoprene (5)
  • Sapphire (11)
  • Silicone (2)
  • SilQ (11)
  • Solva (1)
  • Solvent Flex (4)
  • TFE (3)
  • Tygon (1)
  • Vespel (1)
  • Viton (18)
Model Compatible With
  • AAnalyst 100 (4)
  • AAnalyst 200 (4)
  • AAnalyst 300 (4)
  • AAnalyst 400 (4)
  • AAnalyst 600 (2)
  • AAnalyst 700 (5)
  • AAnalyst 800 (4)
  • AS-93+ (1)
  • AS-S10 (1)
  • ASX-110FR (3)
  • ASX-1400 (3)
  • ASX-1600 (1)
  • ASX-260 (2)
  • ASX-280 (2)
  • ASX-510 (2)
  • ASX-520 (2)
  • ASX-560 (3)
  • ATD 400 (1)
  • Avio (93)
  • Avio 200 (202)
  • Avio 500 (198)
  • Clarus GCMS (1)
  • ELAN (1)
  • ELAN 5000 (122)
  • ELAN 6x00 (125)
  • ELAN 9000 (144)
  • ELAN 9000 Controller Side (2)
  • ELAN 9x00 (1)
  • ELAN DRC II (132)
  • ELAN DRC-e (138)
  • ELAN DRCs (8)
  • EXR-8 (1)
  • FAST (5)
  • LAMBDA 265 (1)
  • LAMBDA 365 (1)
  • LAMBDA 465 (1)
  • Model 3100 (2)
  • Model 3110 (2)
  • Model 3300 (2)
  • Model 5100 PC (2)
  • NexION (3)
  • NexION 1000 (194)
  • NexION 2000 (219)
  • NexION 300 (180)
  • NexION 350 (187)
  • NexION RF Generator Side (1)
  • Optima (4)
  • Optima 2100 (1)
  • Optima 2x00 (3)
  • Optima 2x00 DV (135)
  • Optima 3000 (4)
  • Optima 3000 DV (5)
  • Optima 3000 SCR (8)
  • Optima 3000 SCX (8)
  • Optima 3000 XL (2)
  • Optima 3x00 DV (40)
  • Optima 3x00 RL (17)
  • Optima 3x00 XL (9)
  • Optima 4300 V (42)
  • Optima 4x00 (4)
  • Optima 4x00 DV (227)
  • Optima 5300 V (41)
  • Optima 5x00 (4)
  • Optima 5x00 DV (233)
  • Optima 7000 (1)
  • Optima 7000 DV (2)
  • Optima 7100 (2)
  • Optima 7200 (2)
  • Optima 7300 DV (2)
  • Optima 7300 V (43)
  • Optima 7x00 (4)
  • Optima 7x00 DV (228)
  • Optima 8000 (3)
  • Optima 8300 (2)
  • Optima 8x00 (231)
  • PinAAcle 500 (2)
  • PinAAcle 900F (2)
  • PinAAcle 900H (1)
  • PinAAcle 900T (1)
  • PinAAcle 900Z (1)
  • Plasma 40 (1)
  • Plasma 400 (1)
  • Sample Preparation Blocks (2)
  • SQ 8 (1)
  • TGA 8000 (1)
  • XLR-8 (1)
  • XLR-860 (1)
Number of Elements
  • Multiple (39)
  • Single (383)
Pipetting Arms
Product Brand Name
  • Ari Mist (1)
  • Asperon (2)
  • Avio (2)
  • Capricorn (1)
  • Cinnabar (3)
  • Conikal (5)
  • D-Torch (22)
  • DigiFILTER (1)
  • DuraMist (6)
  • Elegra (1)
  • ESI (5)
  • FIAS (1)
  • GemCone (4)
  • GemTip (23)
  • IsoMist (16)
  • MEINHARD (38)
  • MetalFree (4)
  • MicroFlow (40)
  • MicroFlow-ST (14)
  • MicroMist (21)
  • Mira Mist (9)
  • NEN Radiochemicals (1)
  • NexION (2)
  • OilPrep (3)
  • OpalMist (15)
  • Peltier (32)
  • pergo (8)
  • PerkinElmer (7)
  • S10 (1)
  • SeaSpray (13)
  • Slurry (3)
  • SPB (1)
  • Teledyne CETAC (18)
  • Titan (1)
  • Tracey (8)
  • Twinnabar (2)
  • Twister (14)
  • Valco (1)
  • VeeSpray (2)
  • ZipTorch (5)
Product Group
  • Accessories (1)
  • Adapters (19)
  • Adapters and Replacement Parts (24)
  • Aqueous (353)
  • Autosamplers (6)
  • Blowers and Vents (2)
  • Bonnets (3)
  • Bottles and Containers (2)
  • Capillary Assemblies and Tubing (52)
  • Cleaning Tools (4)
  • Compressor Replacement Parts (5)
  • Cooling Systems (3)
  • Desolvation Accessory (3)
  • Detector Kit (1)
  • Drain Lines (3)
  • Drain Tubing (1)
  • End Caps (1)
  • Ferrules (6)
  • Filter Replacement Part (3)
  • Filters (1)
  • Flow Injection Tubing (8)
  • Gas Lines (3)
  • Gas Lines and Tees (5)
  • Gas/Liquid Separator and Replacement Parts (1)
  • ICP-OES Compressors (7)
  • Injectors (35)
  • Inorganic (20)
  • Instrument Filters (3)
  • Internal Standard Kits (6)
  • Ion Lens Tools (2)
  • Ion Lenses (3)
  • Metal Spill Tray (1)
  • Metallo-Organic (66)
  • Mixing Tees (1)
  • Nebulizer Tips (3)
  • Nebulizers (134)
  • O-Rings (39)
  • O-Rings & Gaskets (9)
  • oneFAST Systems (3)
  • Online Mixing Kits (2)
  • Outer Tubes (7)
  • Peristaltic Pump Tubing (12)
  • Power Conditioner (7)
  • Probes (9)
  • Probes and Sample Tools (1)
  • Pumps (2)
  • Purge Windows (9)
  • Rapid Sample Introduction Systems (10)
  • Regulators (5)
  • Removal Tools (2)
  • Replacement Parts (21)
  • Rotors and Stators (7)
  • Safety Shield (5)
  • Safety Shields (2)
  • Sample Introduction Kits (56)
  • Sample Trays (1)
  • Sampler Cones (4)
  • Screws (1)
  • ShadowStops (2)
  • Skimmer Cones (7)
  • Software and Informatics (3)
  • Spares Kits (2)
  • Spray Chamber Mounts (5)
  • Spray Chambers (77)
  • Temperature Controlled Spray Chambers (46)
  • Torch Ignitor Tape (2)
  • Torch Modules (7)
  • Torch Mounts (15)
  • Torch Replacement Parts (12)
  • Torch Tools (3)
  • Torches (58)
  • Tubes and Vials (4)
  • Tubing (2)
  • Tubing and Replacement Parts (4)
  • Tubing Kits and Spares (5)
  • Ultrasonic Nebulizers (2)
  • UPS System (1)
  • Vacuum Pumps (1)
  • Valves and Replacement Parts (5)
Radioisotope
  • Y-90 (1)
Radionuclide
  • 90Y (1)
Style
  • 0-Slot (19)
  • 1-Slot (13)
  • 2-Slot (1)
  • 3-Slot (12)
  • Conical Bottom (4)
  • Flared (8)
  • Standard (14)
Technology
  • Autosampler (1)
  • ICP Mass Spectrometry (1)
  • ICP Optical Emission Spectroscopy (1)
  • Mercury Analysis Systems (1)
Technology Type
  • AA (7)
  • AA/ICP-OES (224)
  • Atomic Absorption (1)
  • Atomic Spectroscopy (2)
  • Gas Chromatography (GC) (1)
  • ICP (4)
  • ICP Mass Spectrometry (5)
  • ICP Optical Emission Spectroscopy (2)
  • ICP-MS (442)
  • ICP-OES (346)
Technology
  • Autosampler (1)
  • ICP Mass Spectrometry (1)
  • ICP Optical Emission Spectroscopy (1)
  • Mercury Analysis Systems (1)
Type
  • Accessories (2)
  • Baffled and Cyclonic (42)
  • Barrel (4)
  • Cyclonic (20)
  • MP2?Two-Stop (3)
  • Peristaltic Pump Tubing (1)
  • Scott (10)
  • Standard Three-Stop (3)
  • Standard Two-Stop (12)
Volume
  • 201-250 (1)
Volume Capacity
  • 1 Gal (1)
  • 100 g (7)
  • 100 mL (4)
  • 100 μg/g (1)
  • 125 mL (249)
  • 15 mL (2)
  • 20 mL (1)
  • 200 g (6)
  • 250 mL (1)
  • 400 g (8)
  • 5 Gal (3)
  • 50 g (33)
  • 50 mL (4)
  • 500 mL (122)
Standard Type
  • AA Standards (1)
  • Aqueous (1)
  • Biodiesel (2)
  • Biodiesel Blends for IR (1)
  • Contract Required Detection Limits (1)
  • Environmental (1)
  • Fuel Dilution (2)
  • Instrument Calibration (8)
  • Internal Standards (1)
  • Matrix Oils and Solvents (2)
  • Metal Additive (1)
  • Metal Additive Standards (2)
  • Multi-Element (7)
  • Nitric Acid Blanks (1)
  • Particle Analysis (2)
  • Single-Element (383)
  • Spike (1)
  • V-21 Wear Metal (19)
  • Water Pollutant (3)

1-25 of 1394 Products & Services

Sort by

  • Oils7400Autosampler

    Oils 7x00 Series Dual Homogenizing Autosamplers for ICP-OES

    The Oils 7x00 Series Dual Homogenizing Autosamplers are the ideal automation solution for today’s lubricant testing labs that need to accommodate different types of samples – they are engineered to allow two sample matrices (oil and coolant) to be introduced from the same system into the ICP, and are the perfect complement to PerkinElmer’s Avio? 500 ICP-OES Oils system.
  • V-21 Wear Metal Standards Concentration 10 μg/g -100g

    The V-21 Wear Metal Standards from PerkinElmer are ideally suited for the analysis of metal additives, wear metals and contaminants in engine oils by ICP-MS. ??
    List Price : 140.00 USD
  • Oil Standard Sulfur Concentration 1000 μg/g -50g

    The Sulfur (S) Metallo-Organic Standard from PerkinElmer is ideal for your ICP-MS applications.
    List Price : 57.00 USD
  • Glass Twister Spray Chamber for Optima

    O-Ring Free Glass Twister Spray Chamber with Helix for Optima 4300/5300/7300 V

    This o-ring-free 50 mL borosilicate glass Twister? spray chamber, with integrated Helix?, is used with Optima? 4300 V, 5300 V, and 7300 V ICP-OES series instruments.

    List Price : 793.00 USD
  • Organics Glass Twister Spray Chamber for Optima

    Standard Organics Glass Twister Spray Chamber with Helix for Optima 2x00/4x00/5x00/7x00 DV/8x00

    This standard 50 mL glass Twister spray chamber, with integrated Helix?, is designed for organics applications for use with Optima? 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments. It is included in the Organics Sample Introduction Kit for Optima? 8x00 (N0780608) and the Organics Sample Introduction Kit for Optima? 2x00/4x00/5x00/7x00 DV (N0770420).

    List Price : 744.00 USD
  • 0900593

    Metal Ball Joint Clip with Lock

    This stainless steel 12/5 Clamp is for use with PerkinElmer ICP-OES series instruments. It is designed to connect the spray chamber and the torch.
    List Price : 42.00 USD
  • Syringe Flush Kit

    This Syringe Flush Kit is for use with PerkinElmer ICP-OES and ICP-MS instruments. This kit includes the syringe as well as a red and white adapter for different purposes when cleaning your nebulizer. Use the syringe and white adapter to back-flush the carrier line or tee-line. Use the syringe and red adapter to forward flush the carrier line, the side port of the tee-line and to forward flush the PFA nebulizer.

    List Price : 41.00 USD
  • Standard Injector Support Adapter for Optima 2x00/4x00/5x00/7x00/8x00

    This Injector Support Adapter is for use with Optima? 2x00/4x00/5x00/7x00 DV and Optima? 8x00 ICP-OES series instruments. This support adapter is for standard injectors and is compatible with all spray chamber types.

    List Price : 355.00 USD
  • PerkinElmer

    Barium (Ba) Pure Standard

    Each Single Element Calibration Standard for AA and ICP-OES is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

    List Price : 92.00 USD
  • Glass Tracey Spray Chamber for Optima

    50 mL Glass O-ring Free Spray Chamber with Helix for Optima 2x00/4x00/5x00/7x00 DV/8x00

    This 50 mL glass Tracey? cyclonic spray chamber, with integrated Helix?, is used with Optima? 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.

    List Price : 660.00 USD
  • PerkinElmer

    1.2 mm I.D. Entire Length Injector Support Adapter for Optima 2x00/4x00/5x00/7x00/8x00

    This Injector Support Adapter is for use with Optima? 2x00/4x00/5x00/7x00 DV and Optima? 8x00 ICP-OES series instruments. This support adapter is for 1.2 mm I.D. Entire Length Injectors and is compatible with all spray chamber types.

    List Price : 72.00 USD
  • V-21 Wear Metal Standards Concentration 50 μg/g -200g

    The V-21 Wear Metal Standards from PerkinElmer are ideally suited for the analysis of metal additives, wear metals and contaminants in engine oils by ICP-MS. ??
    List Price : 151.00 USD
  • Syngistix_ICPImage1000x1000

    Syngistix for ICP Software

    Syngistix? for ICP software, is a workflow-based software for our Avio? ICP-OES spectrometers as well as LPC 500? liquid particle counter when coupled with the Avio 500 ICP-OES Oils system, designed to improve efficiencies in the laboratory. Flexible and easy to use, Syngistix adds a whole new level of simplicity and productivity for both elemental analysis by ICP and particle counting by SPOS. The software's intuitive interface mirrors the progression of the workflow, guiding users through each step for greater control and confidence.
  • GemTip Cross-Flow Nebulizer O-Ring Kit

    This GemTip Nebulizer O-Ring Kit is for use with Optima? 4x00/5x00/7x00 DV, Optima? 8x00, and Avio? 200/500 ICP-OES series instruments

    List Price : 104.00 USD
  • PFA FG Gas Quick Connect for MEINHARD Nebulizers

    This Gas Quick Connect is designed for use with MEINHARD? Nebulizers in Optima? 4x00/5x00/7x00/8x00 and Avio? 200/500 ICP-OES series instruments, as well as ELAN? 5000/6x00/9000/DRCs and NexION? 300/350/1000/2000 ICP-MS series instruments.

    List Price : 64.00 USD
  • EzyFit Twin Sample Tube - 0.50 mm I.D. x 1?16 in. O.D. x 700 mm Long, Qty. 6

    This EzyFit Twin Sample Tube is for use with MicroMist? and SeaSpray? nebulizers in Optima? 4x00/5x00/7x00/8x00 and Avio? 200/500 ICP-OES series instruments in addition to ELAN? 5000/6x00/9000/DRCs and NexION? 300/350/1000/2000 ICP-MS series instruments. It includes 6 sample tubes.

    List Price : 154.00 USD
  • PerkinElmer

    Tungsten (W) Pure Standard

    Each Single Element Calibration Standard for AA and ICP-OES is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

    List Price : 219.00 USD
  • MEINHARD Glass Type K

    MEINHARD Concentric Glass Nebulizer, Type K1 LDV

    This MEINHARD? Concentric Nebulizer, with 0.7 L/min Argon flow rate and 1 mL/min uptake rate, is for use with Optima 4x00/5x00/7x00/8x00 and Avio 200/500 ICP-OES series instruments. Type K nebulizers are for high solids and low argon flow.

    List Price : 577.00 USD
  • N0770610

    Quick Disconnect Tubing without Swagelock

    This Quick Disconnect Tubing is for use with Avio? and Optima? ICP-OES series instruments. This tubing does not have Swagelok fittings.

    List Price : 111.00 USD
  • Inorganic Aqueous Standards

    Cobalt (Co) Pure Plus Standard

    Each Single Element Calibration Standard for ICP-MS is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

    List Price : 81.00 USD
  • Type A0.5 MEINHARD Quartz Nebulizer for NexION 300/350

    This MEINHARD? Quartz Nebulizer, with 0.5 mL/min uptake rate, is for use with NexION? 300/350 ICP-MS series instruments. The MEINHARD? Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%).

    List Price : 585.00 USD
  • PerkinElmer

    Scandium (Sc) Pure Standard

    Each Single Element Calibration Standard for AA and ICP-OES is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

    List Price : 659.00 USD
  • Sulfur @ 20 ug/g in Biodiesel - 100mL

    We offer the high quality Sulfur (S) in Biodiesel Standard for ICP-MS applications, including determination of interferences.
    List Price : 106.00 USD
  • PerkinElmer

    Cadmium (Cd) Pure Standard

    Each Single Element Calibration Standard for AA and ICP-OES is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

    List Price : 208.00 USD
  • Alumina Injector for Optima 2x00/4x00/5x00/7x00 DV

    This Alumina Injector is for use with Optima? 2x00/4x00/5x00/7x00 DV ICP-OES series instruments. Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene.
    Price Range : 183.00 USD - 237.00 USD
  • Jump to:
Business Insights (31)
Filters:

Filters :

Resource Library
  • Application Note (22)
  • Brochure (1)
  • Case Study (2)
  • Flyer (3)
  • White Paper (3)

1-25 of 31 Business Insights

Sort by

  • Application Note

    Transport of Nanoparticles From Coated Surfaces Through Physical Contact

    This work investigated the transfer of Ag and CuO nanoparticles from consumer products via simulated dermal contact by using textile wipes as a surrogate using PerkinElmer’s NexION ICP-MS single particle analyzer with the unique Syngistix Nano Application software module for data collection and analysis

  • Application Note

    Impurities in Lead with the Avio 500 ICP-OES Following London Metal Exchange Guidelines

    The London Metal Exchange issues specifications for a number of different metals in several grades. This work focuses on the analysis of lead of different purities with PerkinElmer’s Avio? 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Standard Lead1” as a guideline for the analytes and concentrations.

  • Application Note

    Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

    The analysis of soils for elemental contents presents challenges during the sample preparation step. A common method for preparing a soil sample for inorganic elemental analysis involves digesting the soil sample in an acid that is heated to near-boiling to extract the elements for analysis. When using open vessels in heating blocks, this extraction method typically takes four hours or more to complete. The sample must then be centrifuged or filtered to remove solid particles prior to analysis. The use of a microwave digestion system can speed this up significantly by completing the acid digestion in less than 50 minutes.

  • Application Note

    Microwave Digestion - EPA Method 3052 on the Multiwave 3000

    Microwave sample preparation provides an efficient and clean sample preparation for multi-element analytical techniques such as ICP-OES and ICP-MS. As Microwave assisted digestion has evolved, so have the methodologies. EPA method 3052 is designed for the “total” analysis in a variety of matrices including soil, sediments, sludge, oils, biological and botanical materials. This method is the most versatile and has been well proven. It allows variations in reagents and methodology, making it ideal for a variety of matrices and elements. The variability of this method also requires a basic understanding of digestion chemistry.

  • Application Note

    Using MSF to Resolve Difficult Interferences in Metallurgical Samples with the Avio 500 ICP-OES

    The analysis of trace metals in metallurgical matrices also presents a challenge for ICP-OES: spectral interferences. Many elements have a large number of emission lines (i.e. approximately 20,000 for iron), which increases the potential for spectral interferences. This effect is compounded in metallurgical samples, where the matrix element(s) are present at high levels due to the minimal dilutions used.

  • Application Note

    Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

    This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and more ENPs have been released into the environment, which raises concerns over their fate, toxicity and transport therein.

  • Application Note

    Analysis of Drinking and Natural Waters using the NexION 2000 ICP-MS

    This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, with stability of at least nine hours. Method detection limits allow for trace-level determinations, while the ability to selectively suppress user-defined isotopes also allows the measurement of analyte levels usually only possible by ICP-OES or Flame AA. The NexION 2000 provides a comprehensive solution to the challenge of U.S. EPA Method 200.8 and other drinking and natural water analytical requirements across the globe.

  • Flyer

    OilPrep 4 Oil Diluter Flyer

    Need flexible sample preparation for wear metals and particle count analyses? The OilPrep? 4 is a dedicated four-tip oil diluter that automatically dilutes oil samples with kerosene (V-Solv? ICP solvent), in preparation for wear metals and particle counting/sizing analyses by inductively coupled plasma (ICP-OES) and single particle optical sizing (SPOS), such as with the Avio? ICP-OES and LPC 500? Liquid Particle Counter.

    Some key benefits include:

    • • High throughput – Significantly improves productivity and efficiency versus manual or single-tip systems. Diluting up to 250 samples per hour, one OilPrep 4 oil diluter can prepare approximately 2000 samples in 8 hours.
    • • Flexibility – Innovative Varispan? technology provides automatic computer-controlled variable sample probe spacing for multi-tipped processing of original sample containers.
    • • Time Savings – Unlike alternate technologies, PerkinElmer’s Ultrasonic Liquid Level Sensing is not impacted by individual sample viscosities, color, or external lighting.

    Download the flyer to discover more.

  • White Paper

    Single Particle Inductively Coupled Plasma Mass Spectrometry: Understanding How and Why

    Analyzing single nanoparticles with ICP-MS requires a different approach than measuring dissolved elements. This work describes the theory behind single-particle ICP-MS measurements, drawing comparisons and differences with analyzing dissolved elements.

  • Application Note

    Analysis of Impurities in Nickel with Avio 500 ICP-OES Following London Metal Exchange Guidelines

    The London Metal Exchange (LME) issues specifications for a variety of purities for different metals. This work focuses on the analysis of contaminants in nickel with PerkinElmer’s Avio? 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Primary Nickel” as a guideline for the analytes and required concentrations.

  • Application Note

    Analysis of In-Service Oils Following ASTM D5185 with the Avio 500 ICP-OES

    Globally, heavy machinery is used in construction, mining, and a variety of other areas. As the scale of the operations increase, the size, complexity, and cost of the equipment also increase, meaning that breakdowns can be costly, both in equipment repair and lost revenue. As a result, preventive maintenance is paramount. Lubricants are among the key fluids that can be tested, especially the oil used in engines. By monitoring the elemental concentration of the oil or other lubricants (hydraulics, transmission, gear), the status of that compartment can be determined.

  • Application Note

    The Determination of Lead in Calcium-Based Antacid and Dietary Supplements Using the NexION 350 ICP-MS System to Comply with the State of California's Proposition 65 Legislation

    Compliance with California’s Proposition 65 for the monitoring of lead (Pb) in calcium-based antacid medications and dietary supplements requires the analytical methodology to demonstrate detection limits below 0.05 μg/g in the solid material. The analytical capabilities of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) make it the most suitable technique for performing lead determinations at these low levels on a routine basis.

  • Application Note

    Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES

    When blending base oils and additives for use as lubricants, it is important to know and control the concentrations of certain elements for optimal performance and longer engine life. This work will focus on the analysis of additives in new oils using PerkinElmer’s Avio? 200 ICP Optical Emission Spectrometer (ICP-OES), which overcomes limitations of other ICP-OES systems and X-ray analyses.

  • Application Note

    Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

    In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work studies the release of TiO2 NPs from various commercial textile products which do not advertise that TiO2 NPs have been added.

  • Application Note

    Accurate Sizing and Precise Counting of 10 nm Gold Nanoparticles using the NexION 2000 ICP-MS

    In this work, we demonstrate that PerkinElmer's NexION? 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix? Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of various sizes.

  • Application Note

    New Research Evaluating Cisplatin Uptake in Ovarian Cancer Cells by Single Cell ICP-MS

    Cisplatin, carboplatin, and oxaliplatin are the most widely used of platinum-based cancer chemotherapy drugs in the Western world. Cisplatin's effectiveness is due to its ability to bind to the DNA, resulting in DNA-platinum (Pt) adducts, which bend the DNA. The cells must then repair the DNA damage, otherwise DNA replication is blocked resulting in cell death. Many cancers are initially sensitive to platinum-based treatment, but patients frequently relapse with tumors displaying resistance to further cisplatin therapy.

  • Brochure

    OilExpress 4 Oil Condition Monitoring System

    The OilExpress 4 system adapts to your laboratory’s needs, from dozens to thousands of samples per day. Its modular design makes it possible to scale up your sample throughput or separately utilize the oil dilution capabilities in busy laboratories that are using ICP analysis. The system minimizes your operational costs by reducing instrument downtime, increasing throughput to reduce cost per sample, and offering significant savings from decreased solvent waste.

  • Application Note

    Analysis of Single-Walled Carbon Nanotubes with SP-ICP-MS

    Measuring the amount of metals in CNTs presents a challenge. High levels can be measured directly in the solid by several techniques, including XRF and TEM, while low-level analysis requires complete digestion of the sample prior to analysis by ICP-OES or ICP-MS.

  • White Paper

    An Introduction to Single Cell ICP-MS Analysis

    In this white paper, we will introduce the concept of Single Cell ICP-MS (SC-ICP-MS), where individual cells are rapidly analyzed for metal content.

    Research into the effectiveness of anti-cancer medications is explored by monitoring the uptake rate of cisplatin at the cellular level, advancing the knowledge of cellular interactions with metal-containing species. SC-ICP-MS allows users to monitor metal content within single cells for intrinsic metal content, uptake of ionic and/or nanoparticulate contaminants, handle lower cell numbers compared to conventional methods, and use minimal sample preparation.

  • Flyer

    5 Tips to Improving Your Sample Digestion

    Sample preparation is one of the most critical steps in your analytical process. Often accounting for 60% of your analytical timetable, it has a fundamental impact on laboratory throughput and analytical performance. Any errors within the sample preparation process will undermine the quality of your food data at all subsequent stages of your analysis. Here are five tips to improving your sample digestion for food samples.

  • Application Note

    Analysis of Wastewaters Following US EPA 200.7 Using the Avio 500 ICP-OES

    This work focuses on the analysis of wastewaters following the guidelines provided in U.S. EPA Method 200.7. The U.S. Environmental Protection Agency (EPA) developed Method 200.7 for the determination of metals and trace elements in waters and wastes by ICP-OES, with the current version being Revision 4.4.1 While the scope of this method allows it to be applied to a variety of sample types, a common application is wastewater analysis.

  • Flyer

    NexSAR HPLC-ICP-MS Speciation Solution

    Speciation studies can provide comprehensive information regarding ion mobility, bioavailability, and toxicity. Consequently, many modern labs are expanding their analytical portfolio to include HPLC-ICP-MS. For such studies, it is advantageous to have an intuitive, user-friendly system that meets the user requirements for automation, ultra-low baseline, powerful integration, and flexible data export. And no one offers a more integrated, versatile, and inert speciation solution than PerkinElmer - accelerate your speciation analysis with the NexSAR? HPLC-ICP-MS Speciation Solution.

  • Application Note

    The Application of ASTM Standard D7720 to Used Oil Data Using TIBCO Spotfire?

    The importance of managing and utilizing such data is emphasized by the creation of ASTM standard D7720, Statistically Evaluating Measurand Alarm Limits when Using Oil Analysis to Monitor Equipment and Oil for Fitness and Contamination. This application note demonstrates the transformation of used oil data in accordance with the aforementioned ASTM standard using data visualization software program TIBCO Spotfire?.

  • White Paper

    Weighing the Benefits and Risks of Nanotechnology White Paper

    There is a growing body of evidence showing that there are significant differences between some nanomaterials and their non-nanoscale counterparts. What those differences portend raises many new questions about their potential to cause harm to human health and the environment.

  • Application Note

    Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES

    With heavy machinery, it is important to assess its status during operation to prevent breakdowns and costly repairs. A key aspect is monitoring the status of the oil or lubricants used to lubricate various components such as engines, transmissions, gearboxes and many other important areas: if the oil degrades too much or becomes highly contaminated, it can damage various components. Because of its importance, ASTM created a method for the analysis of in-service oils: method D5185.

  • Jump to: