PerkinElmer

Search Results for 'DSC'

Products & Services (40)
Filters:

Filters :

Show results for
Product Type
  • Accessories (17)
  • Consumables (18)
  • Instruments (5)
Material
  • Aluminum (9)
  • Gold (1)
  • Platinum (2)
  • Stainless Steel (1)
Minimum Temperature (Celcius)
  • 10-20 (1)
Maximum Temperature (Celcius)
  • Over 100 (5)
Model Compatible With
  • Diamond DSC (12)
  • DSC -4 RS (4)
  • DSC 4000 (3)
  • DSC 6 (7)
  • DSC 6000 (3)
  • DSC 7 (7)
  • DSC 7 RS (3)
  • DSC 8000 (6)
  • DSC 8500 (6)
  • Jade DSC (7)
  • Pyris 1 (2)
  • Pyris 1 Autosampler (1)
  • Pyris 1 DSC (9)
  • Pyris 6 DSC (7)
  • Pyris DSC (1)
Pipetting Arms
Product Group
  • Calibration (TEA) (4)
  • Cooling Systems (7)
  • Cover Kit (1)
  • Covers (2)
  • GC Compressors (2)
  • Guard Rings (1)
  • Pan Crimpers (1)
  • Sample Holder Cover (1)
  • Sample Holder Covers (1)
  • Sample Loading Tool (1)
  • Sample Pans (10)
  • Starter Kit (1)
Technology
  • Thermal Analysis (4)
Technology Type
  • DSC (15)
  • Thermal Analysis (5)
Technology
  • Thermal Analysis (4)
Volume Capacity
  • 30 μL (2)
  • 40 μL (3)
  • 50 μL (2)
Standard Type
  • Reference Materials (4)

1-12 of 40 Products & Services

Sort by

  • Autosampler Aluminum Sample Pans

    These Autosampler sample pans are used to prepare sample materials for your DSC Autosampler. These pans are sealed and may also be used for non-robotic systems. The pans have an operating range of -170 °C and a volume of your choice and can withstand a pressure of 1 bar. These aluminum sample pans can also be used with crimper (B0139005) and requires cover (B0143003).
    List Price : 259.00 USD
  • PerkinElmer

    Lead Calibration Reference Material, Transition Point: 327.47°C

    PerkinElmer reference materials are 99.999% pure. DSC requires elements of this purity so that the instrument can be accurately calibrated. Depend on PerkinElmer for quality calibration reference materials.
    List Price : 47.00 USD
  • Aluminum Sample Pans and Covers, 400 ea.

    Includes 400 pans and 400 covers. These aluminum pans and covers have a temperature range of -170° to 600 °C, 40 μL volume, and an ambient maximum pressure. Compatible with our crimpers and sealers (02190048) or (B0139005 with B0508921).
    List Price : 506.00 USD
  • PerkinElmer

    Zinc Calibration Reference Material

    Ensure accurate thermogravimetric measurements with PerkinElmer magnetic reference materials. Transition point of 419.47°C.
    List Price : 58.00 USD
  • PerkinElmer

    Guard Rings for Diamond DSC, Pkg. 2

    Includes 2 guard rings. These guard rings are for use with the Diamond DSC and they protect the sample holder cavity by preventing sample from falling into the cavity causing damage to the sample and reference furnaces.
    List Price : 112.00 USD
  • PerkinElmer
    List Price : 277.00 USD
  • PerkinElmer
    List Price : 3586.00 USD
  • PerkinElmer

    Intracooler Bolt Kit for the Pyris 1 DSC and DSC 7

    Includes: Intracooler Bolt Insulating Disk (P/N 03191720), Split Bushing (P/N 03191719), and Bolt (P/N 03191527)
    List Price : 278.00 USD
  • PerkinElmer
    List Price : 702.00 USD
  • Sample Holder Cover Reforming Tool

    The Sample Holder Cover Reforming Tool is used with the Pyris 1 DSC, Diamond DSC, DSC 8000 and DSC 8500. DSC performance is enhanced with sample holder covers that are formed properly and not degraded by extended usage.
    List Price : 887.00 USD
  • Platinum Cover for Sample and Reference Cells, 1 ea.

    For use with the Pyris 1 DSC Autosampler. Two required for each sample holder. Use these pans and covers when gold and graphite pans and covers are not suitable. Used to analyze mineral, soil, and ceramic samples. Also used to allow a chemical reaction where platinum acts as a catalyst. Covers are easy to clean and are reusable. A crimper is not required.
    List Price : 294.00 USD
  • DSC 8000 - Differential Scanning Calorimeter

    DSC 8000

    The DSC 8000, double-furnace, power compensation DSC provides greater sensitivity and accuracy as well as faster and more reliable results then you ever thought possible.
  • Jump to:
Business Insights (6)
Filters:

1-6 of 6 Business Insights

Sort by

  • Application Note

    HyperDSC for High Throughput Formulation Development

    The concept of High-Throughput Design has gained more and more interest as a way to increase profitability and to decrease research costs. One technique that can increase the ability of a laboratory to evaluate formulations is HyperDSC? or High Ramping Rate DSC. HyperDSC is the ability to quantitatively measure small samples at extreme heating and cooling rates, typically 100-500 °C/min.

  • Application Note

    Curing Determination of EVA for Solar Panel Application

    This study shows that DSC can be used to study the curing degree of the EVA resin by measuring the residual curing enthalpy. The data show that the residual curing enthalpy can be correlated to the curing time in a linear way. The DSC test is quick and easy.

  • Application Note

    High Resolution Characterization of Pharmaceutical Polymorphs Using Power Compensation DSC

    Many pharmaceutical materials exhibit polymorphism, which means that, depending upon the given processing conditions, the crystalline form may exist in two or more states. The crystalline states or forms exhibit different levels of thermodynamic stabilities and an unstable form can melt at a temperature significantly less than the melting point of the thermodynamically stable form. Depending upon the conditions used to generate the crystalline form(s), the drug may exhibit one or more unstable, polymorphic crystalline states.

  • Application Note

    Pharmaceutical Compounds are Analyzed in Half the Time by Simultaneous TGA-DSC

    In the “Early Drug Discovery Phase” of pharmaceutical development when there is a minimum amount of synthesized drug candidate, quick thermal analysis using a small amount of sample is the norm. The sample amount could be less than 3 mg. Because of the rush to identify possible drug candidates, analytical answers must be given within the day. The STA 6000 with its sensitivity of 0.1 μg allows minimum sample material to obtain reproducible results in half the time.

  • Application Note

    Improved HyperDSC Method to Determine Specific Heat Capacity of Nanocomposites and Probe for High-Temperature Devitrification

    Where ΔCp and ΔCp pure are the changes in specific heat at the glass transition temperature, Tg, for the composite, and for the unfilled polymer, respectively. This work suggests an alternative method for determining Cp that takes advantage of fast heating and cooling rates to obtain quantitative Cp in the upper temperature region without having to dwell in that high temperature region to establish an upper isothermal.

  • Application Note

    Study Rigid Amorphous Fraction in Polymer Nano-Composites by StepScan and HyperDSC

    Heat capacity measurement has been performed in order to detect a possible second Tg on nanocomposites of polymethyl methacrylate (PMMA) with silicon oxide nanoparticles of different shape. StepScan? DSC was used for determination of precise heat capacity and HyperDSC? to prevent degradation and identify devitrification of the RAF at elevated temperatures.