PerkinElmer

吉林快三计划三期计划:Sample Holder Supplies

OF

吉林快三走势图综合板 www.saanl.com Our sample holder supplies span both analytical and biological instrumentation.

  • For analytical testing, we offer a wide array of sample holder supplies for thermal, elemental, and infrared instruments.
  • For biological testing, we offer sample holder supplies for laboratory automation systems.

Products & Services (112)
Filters:

Filters :

Product Type
  • Accessories (48)
  • Consumables (61)
  • Instruments (3)
Model Compatible With
  • LAMBDA 1050 (3)
  • LAMBDA 25 (2)
  • LAMBDA 35 (2)
  • LAMBDA 45 (2)
  • LAMBDA 465 (1)
  • LAMBDA 650 (3)
  • LAMBDA 750 (2)
  • LAMBDA 800 (1)
  • LAMBDA 850 (3)
  • LAMBDA 900 (1)
  • LAMBDA 950 (3)
  • Spectrum One (1)
Product Group
  • Cell Changers (5)
  • Cell Holder (1)
  • Cell Holders (7)
  • Fiber Optic Accessory (1)
  • Flexar SQ 300 MS Accessories (2)
  • Imaging Accessories (4)
  • Integrating Sphere (1)
  • Monofibers (1)
  • NIR Accessory (1)
  • Powder Sample Holder (1)
  • Reflectance Accessory (3)
  • Sample Holder (11)
  • Small Spot Accessory Kit (1)
  • Surface Accessory (1)
  • Thermostatting Accessory (1)
  • Transfer-Optic (1)
  • Universal Reflectance Accessory (3)
  • Variable Angle Accessory (1)
Technology Type
  • Diffuse Reflectance (1)
  • Fiber Optics (4)
  • Fluorescence Sampling (1)
  • Integrating Spheres (4)
  • Specular Reflectance (7)

1-25 of 112 Products & Services

Sort by

  • PerkinElmer

    Angular Scattering Option for ARTA

    Arta Angular Scattering Option
  • PerkinElmer

    Sample Tilt Option for ARTA

    Arta Sample Tilt Stage Motorized
  • PerkinElmer
  • PerkinElmer

    Fiber optic reference feed kit

    The kit allows the reference beam to be introduced into the sphere via a flexible fiber optic bundle. This eliminates the need to use mirrors to direct the reference beam into the sphere allowing a wider variety of geometry’s to be used.
  • Fixed Angle Reflectance Holder for LAMBDA 365

    Fixed Angle Reflectance Holder for LAMBDA 365

    Designed for measuring specular reflectance spectra at a fixed angle (incident angle: 30° fixed). An easy-to-use specular reflectance accessory for analysis of solid samples, providing high-quality data for identifying films and coatings, measurement of the film thickness, and surface studies of metals.
  • Water Jacketed 8-Position Multi-Cell Holder for LAMBDA 365

    Water Jacketed 8-Position Multi-Cell Holder for LAMBDA 365

    Accommodates any standard 10 mm cells. It uses recirculating liquid to control the temperature of up to 8 samples.
  • PerkinElmer

    LAMBDA 100mm PbS Integrating Sphere

    Comprising Integrating sphere contained in a module which simply snaps into the spectrometer and is ready to be used without any adjustment. integrating spheres is the industry standard for the measurement of total reflectance, diffuse reflectance and diffuse transmittance measurements for a huge range of sample types. The 60 mm and 100 mm Integrating Sphere are used for routine diffuse reflectance and diffuse transmittance measurements.
  • PerkinElmer

    Magnetic Stirrer Assy, Automatic, 2 Ch for LAMBDA 365

    Contains magnetic stirring controller, stirring head, and magnetic stirring bar for 10 mm pathlength cuvette. It is used with single cell holders to add stirring capability. There are up to 2 cells stirring, with an extra wide speed range of 100 to 1600 rpm. The control unit comes with 20 watts rated stirring power. A graphic display allows all settings to be readable at a glance. The operating temperature range is 0 to 40°C.
  • Cylindrical Long Path Cell Holder

    The Cylindrical Long-Path Cell Holder accommodates cells with outside diameters from 22 to 30 mm. A versatile cell holder, it accepts cells with pathlengths up to 100 mm.
    List Price : 452.00 USD
  • Advanced Transmission Holder for LAMBDA 365

    Advanced Transmission Holder for LAMBDA 365

    The advanced transmission holder is designed to hold materials such as glass, polymers, and films, providing a positive locating point for the sample that can be adjusted to accommodate a range of sizes and thicknesses.
  • PerkinElmer

    Test Tube Holder for test tubes with diameters between 11mm and 17mm

    This holder accommodates test tubes from 11 to 17 mm diameter.
    List Price : 905.00 USD
  • Variable Angle Transmission Holder, 0-75° for LAMBDA 365

    Variable Angle Transmission Holder, 0-75° for LAMBDA 365

    Used for transmittance measurement of various samples of film, glass, plate, etc. at various angles. It adjusts the angle of solid samples for transmission measurements (0~80°). It also accommodates various thickness samples and large samples. This accessory allows reproducible measurement at multiple angles without moving the mounted sample. The angle is easily set by rotating the sample mounting stage.
  • PerkinElmer

    Nano Stick‐D, Z 15 Blue 2 μL 0.5 mm

    Each Nano Stick standard package kit (with case) comes with 1 Nano Stick, 1 loading plate, 1 bubble checker, and a user guide. The preferred color of your choice can be selected (Black, Blue, Red, Gold, or Silver). The Z-Dimension, the height of the center of the light beam, is 15 mm. The beam pathlength is 0.5 mm. Fits standard 10 mm cell holder. D Nano Sticks have dual sampling ports and S have a single sampling port.
    List Price : 1847.00 USD
  • Magnetic Stirrer Assy, Manual for LAMBDA 365

    Magnetic Stirrer Assy, Manual for LAMBDA 365

    Consists of magnetic stirring controller, stirring head, and magnetic stirring bar for 10 mm pathlength cuvette. It is used with single cell holders and multicell holders to add stirring capability. It is ideal for small to medium stirring volumes of low-viscosity liquids. There is a control unit with a rated stirring power of 10 watts. The operating temperature range is 0°C to 40°C.
  • PerkinElmer

    Lens assembly kit

    The kit allows for the focusing of the beam to a small spot by means of a number of plane convex lenses and iris diaphragms. The lenses are mounted on magnetized bases.
  • PerkinElmer
    List Price : 789.00 USD
  • NanoStick-S-Family

    Nano Stick‐S, Z 15 Black 2 μL 0.5 mm

    Each Nano Stick standard package kit (with case) comes with 1 Nano Stick, 1 loading plate, 1 bubble checker, and a user guide. The preferred color of your choice can be selected (Black, Blue, Red, Gold, or Silver). The Z-Dimension, the height of the center of the light beam, is 15 mm. The beam pathlength is 0.5 mm. Fits standard 10 mm cell holder. D Nano Sticks have dual sampling ports and S have a single sampling port.
    List Price : 1458.00 USD
  • PerkinElmer

    DSA Mesh Holder Assembly

    13 position Holder for Sampling screen (MZ305382) for use with on the Direct Sample Analysis (DSA) Ion Source for AxION 2 TOF MS.
  • PerkinElmer

    "Grazing Angle" Relative Reflectance Accessory

    For reflectance of thickness measurements 80° of light incidence.
  • Water Jacketed Single Cell Holder for LAMBDA 365

    Water Jacketed Single Cell Holder for LAMBDA 365

    Maintains temperature control over standard 10 mm cells using recirculating liquid.
  • PerkinElmer

    Combusto-Cone, Flexible, Pack of 1,000

    For supporting liquid samples in combustion baskets. Used in a System 387 sample oxidizer for liquid scintillation counting.
    List Price : 434.00 USD
  • NanoStick-S-Family

    Nano Stick‐S, Z 15 Gold 2 μL 0.5 mm

    Each Nano Stick standard package kit (with case) comes with 1 Nano Stick, 1 loading plate, 1 bubble checker, and a user guide. The preferred color of your choice can be selected (Black, Blue, Red, Gold, or Silver). The Z-Dimension, the height of the center of the light beam, is 15 mm. The beam pathlength is 0.5 mm. Fits standard 10 mm cell holder. D Nano Sticks have dual sampling ports and S have a single sampling port.
    List Price : 1458.00 USD
  • PerkinElmer

    DSA Capillary Tube Holder

    Tube Holder for capillary sample tubes (MZ305385) for use with on the Direct Sample Analysis (DSA) Ion Source for AxION 2 TOF MS. 13 positions.
  • Base Plate for Fixed Angle Reflectance Accessory for LAMBDA 365

    Base Plate for Fixed Angle Reflectance Accessory for LAMBDA 365

    Used for installing Fixed Angle Reflectance Accessory (6°) B0086703.
    List Price : 264.00 USD
  • PerkinElmer

    Combusto-Pad, 500/PK

    Absorbent, combustible pads used when combusting liquid samples for radiometric detection.
    List Price : 67.00 USD
  • Jump to: